Description
Key Benefits
- High service temperatures
- Fire reaction
- Nuclear plant quality
- High flexibility
- Improved logistics
Technical Characteristics
| Symbol | Unit | Quantities and declared values | Standard | |
|---|---|---|---|---|
| Specific thermal capacity | Symbolc | UnitkJ/(kg·K) | Quantities and declared values1.03 | StandardISO 10456 |
| Reaction to fire | Symbol- | Unit- | Quantities and declared valuesNon combustible; Euroclass A1 Fire Spread Index = 0; Smoke Development Index = 0 | StandardEN 13501-1 ASTM E84 |
| Water behaviour | SymbolWS | Unitkg/m² | Quantities and declared values No short term water absorption by partial immersion (WS1 ≤ 1 kg/m2) | StandardEN ISO 29767 |
| Chemical behaviour | Symbol- | Unit- | Quantities and declared valuesDo not contribute to corrosion of stainless steel Produced without addition of silicone Especially designed and certified for use in nuclear applications | StandardASTM C795/871 |
| Application field | Quantities and declared valuesProduct for use in technical applications, such as inaccessible cavities, complicated confined surfaces or dead spaces Especially designed and certified for use in nuclear applications | Standard- | ||
| Material | Quantities and declared valuesLoose stone mineral wool without binder With quality marks EUCEB, unrisky regarding health according to regulation EC No 1272/2008 Note Q | StandardCINI 2.2.04 | ||
| Miscellaneous | Quantities and declared valuesStorage: Bags to be stored indoors in a dry and clean place away from source of humidity | Standard- | ||
| Quality management | Quantities and declared valuesISOVER is certified according to EN ISO 9001 and EN ISO 14001 | StandardEN ISO 9001 EN ISO 14001 | ||
| Delivery form | Quantities and declared valuesPlease contact your local ISOVER dealer All dimensions require minimum order quantities | Standard- |
Thermal Conductivity
| Characteristic | Symbol | Unit | Quantities and declared values | Standard | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CharacteristicThermal conductivity* | SymbolT | Unit[°C] | Quantities and declared values-30 | Quantities and declared values- | Quantities and declared values50 | Quantities and declared values100 | Quantities and declared values150 | Quantities and declared values200 | Quantities and declared values300 | Quantities and declared values400 | Quantities and declared values500 | StandardEN 12667 |
| Symbolλ | Unit[W/(m•K)] | Quantities and declared values0.032 | Quantities and declared values0.035 | Quantities and declared values0.041 | Quantities and declared values0.048 | Quantities and declared values0.056 | Quantities and declared values0.065 | Quantities and declared values0.088 | Quantities and declared values0.119 | Quantities and declared values0.160 | ||
| CharacteristicThermal behaviour | SymbolT | Unit[°C] | Quantities and declared valuesOperating temperature range -200 ºC until +700 ºC | Standard- | ||||||||